1ALBRECHTAE100T500-Channel Programmable ScannerOWNER’S MANUAL
10SEARCH BANK -- appears with numbers (1-10). Numbers with a bar under themshow which search banks are turned on for a limit search.BANK -- appears wi
11CH -- the digits that precede this indicator (1-500) show which channel the scanner istuned to.AM/WFM -- appears when the scanner scans a frequency
12OPERATIONTURNING ON THE SCANNER/SETTING VOLUME AND SQUELCHNote: Make sure the scanner's antenna is connected before you turn it on.1. Turn SQUE
13Note: If you have not stored any frequencies into channels yet, the scanner displaysthe empty channels.Tuning FrequenciesNote: You can use the rotar
14Initializing the ScannerCaution: This procedure clears all information you stored in the scanner’s memory.Initialize the scanner only when you are s
154. Press ENTER to store the frequency.Notes:l If you entered an invalid frequency in Step 3, the scanner beeps and displays thechannel number and Er
16Notes:l To select bank 10, press 0.l If you select a bank that does not contain any empty channels, a bar flashesunder the bank number, and A-FULL a
17Notes:l If no frequencies are stored when you pause auto store by pressing AUTO, ---appears on the display.l During auto store, the scanner beeps wh
183. When the scanner find an active frequency, it stops searching and displays thatfrequency's number.To store that frequency in the channel, s
194. Use the number keys to enter the lower limit of the frequency range you want tosearch, then press ENTER.Note: If you enter an invalid frequency i
2INTRODUCTIONThe AE100T 500-Channel Programmed Scanner enables you to experience all the action foryourself. It is possible to store up to 115,000 fre
20Direct SearchYou can search up or down from the currently displayed frequency and storefrequencies you like into channels or monitor memories.Notes:
21Note: When you store frequency while all channels entered, CH FULL appears. Inorder to store more frequencies, you must clear some channels. See &qu
22To begin scanning channels or to start scanning again after monitoring a specificchannel, press SCAN.Notes:l You must store frequencies into channel
23TURNING CHANNEL-STORAGE BANKS OFF AND ONTo turn off banks while scanning, press the bank's number key until the bar under thebank's number
241. Press AUTO. AUTO appears.2. Pressing AUTO key or turn TUNE knob, to select the channel bank where youwant to store monitor memory frequencies. If
252. Use the number keys to enter the channel number or monitor memory containingthe frequency you want to delete.3. If you are deleting the frequency
261. Press AUTO. AUTO appears.2. Pressing AUTO keys or turn TUNE knob, to select the channel bank.3. Press and hold down ENTER, then press /\ to sort
27SPECIAL FEATURESDELAYMany agencies use a two-way radio system that might have a pause of severalseconds between a query and a reply. Your scanner&ap
28To lock out a frequency during a each search mode, press L/OUT when the scannerstops on the frequency. The scanner locks out the frequency, then con
29With the priority feature, you can scan through programmed channels and still notmiss an important or interesting call on a specific channel. You ca
3S-Meter -- shows receiving signal strength.Tape Remote Jack -- controls your tape recorder when the scanner receives thesignal.Memory Backup -- keeps
30CHANGING THE AM/FM/WFM RECEIVE MODEThe scanner is preset to the most common AM/FM/WFM receive mode for eachfrequency range. The preset modes are:Fre
31Follow these steps to turn the scanner's key tone on or off.1. If the scanner is on, turn VOLUME OFF/MAX counterclockwise until it clicks to tu
32The distance over which it is possible for you to receive messages is restricted toapproximately 25 km. The manner in which the scanner has been pos
33. Only use the scanner in normal temperature conditions. High temperatures, orsudden changes of temperature, will reduce the life span of the scanne
34(500 channels per bank x 10 banks,50 monitor memories and 10 priority channels)Sensitivity:NFM (S+N)/N=20 dB 25-500 MHz 0.5 uVdev. 3 kHz at 1 kHz 50
35500.0125-1000 MHz 25 dB1000.0125-1300 MHz 25 dBWFMThreshold 25-500 MHz 3 uV500.0125-1000 MHz 3 uV1000.0125-1300 MHz 15 uVTight 25-500 MHz 50 dB500.0
422 959-96023 1240-1300The use of this scanner is only authorised if the person concerned complies with allthe provisions which apply within the count
5coaxial cable. For any distance of less than 15 meters, cable of the RG58 type maybe used, whereas for longer cables the use of the thicker RG8 type
62. Press and hold down the [CLEAR] button on the keyboard whilst pressing theRESTART button by means of a pointed object. First release the RESTART b
7UNDERSTANDING YOUR SCANNERA LOOK AT THE KEYPADYour scanner's keys might seem confusing at first, but this information should helpyou understand
8DIRECT/• -- enters a decimal point (necessary when programming frequencies), orstart a direct frequency search.ENTER -- enters frequencies into chann
9ANT -- connect optional antenna with BNC connector.TAPE REMOTE -- connect your tape recorder's remote terminal.TAPE OUT -- connect your tape rec